When there is something wrong with the system, the function of sound alarm should be provided.
eGlobal Navigation Lighting Monitoring System
This kind of system can monitor and control the lights loops of the airport and the operator can observe the situation of the all navigation lightings through the touch screen and control the power and the brightness.
The system includes the tower, maintenance center, the lighting station and synch-control.
A. Display function:
Module chart of flight area
Module chart of lighting equipment
Module chart of lighting control equipment
Equipment sheet
Changing color and lighting alarm
B. Control function
Single-control- the operator of tower can control the switch and brightness of a certain lighting loop separately.
Grouping-control- the operator of the tower can control the switch and brightness of some lighting loops at the same time.
Global-control- the operator of the tower can control the switch and brightness of some lighting loops at one time.
Module-control- the operator of the tower can open the related lighting loop at one time according to the standard of visibility and condition of rising and falling. The control modules can real-time design and modify and then control the lighting loop as this module.
C. Monitoring function
To display the name of lighting loop and monitor the lighting degree of each loop
To monitor the communication situation of the controlled object and the local/ remote control situation
To monitor the problems of loop
To monitor the working situation of maintenance center and lighting station
To monitor the problems of lighting
D. Function of alarm
Aural and visual alarm for the following:-
- The customized light level of dimmer is not accordant with the actual one.
- Something wrong with the dimmer
- Lighting loop is opened.
- PAPI leaning switch
- Angle of PAPI is not correct.
- Something wrong with the lighting point.
E. function of prevent the wrong operation
The system will not accept any wrong man-made operation which can destroy the system.
It will give an alarm when any wrong man-made operation which can destroy the system happens.
Any wrong man-made operation which can destroy the system will be recorded.
F. function of record
Record function of operation information
Function of maintenance center:
A. Monitoring function
To display the name of lighting loop and monitor the lighting degree of each loop
To monitor the communication situation of the controlled object and the local/ remote control situation
To monitor the current and pressure of lighting loop
To monitor the problems of lighting loop
To monitor the problems of lighting point
To monitor the work of each computer
To monitor the work of lighting station
B. Function of alarm:
To alarm and display for the follows:
- Local dimmer
- The customized light level of dimmer is not accordant with the actual one.
- The value of invalid lighting points of loop is beyond the scheduled value.
- The value of invalid flashlights is beyond the scheduled one.
- The authority and retract of the system control right
Aural and visual alarm for the following:-
- Dimmer is under-pressure.
- Dimmer is overpressure.
- Dimmer is over-current.
- Dimmer is opened.
- There are some communicative wrong with the controlled objects.
- PAPI leaning switch
- Angle of PAPI is not correct.
- Dimmer lost the inputting current.
- Computer problems
C. Operation information record function:
To record the operation of turning on the light of loop
To record the operation of turning off the light of loop
To record the operation of loop changes the light level
To record the authority operation of tower
To record the retracting operation of tower
To record the time and place of each operations
D. Alarm information record function:
Local dimmer
The customized light level of dimmer is not accordant with the actual one.
The value of invalid flashlight is beyond the scheduled value.
The authority and retract of the system control right
Dimmer is under-pressure
Dimmer is overpressure.
Dimmer is over-current.
Dimmer is opened
There are some communicative wrong with the controlled objects.
PAPI leaning switch
The angle of PAPI is not correct.
The dimmer lost the inputting current.
Computer problems
To record the alarm time and place.
E. inquiring function:
To inquire according to the equipment
To inquire according to the types of operation
To inquire according to the types of alarm
To inquire according to the time
To inquire according to the manner of combination
F. Data report form and printing function
It can display and print the following data report form
- The report form of real time situation of equipment
- Researching the result report form
- Periodic report form
Function of lighting station:
To display the name of lighting loop and monitor the light level of each loop
To monitor the communication situation of the controlled object and the local/ remote control situation
To monitor the current and pressure of lighting loop
To monitor the active power of lighting loop to make the statistic warning of problems of lighting point of loop
To monitor the problems of lighting loop
To monitor the work of each computer
To monitor work of lighting station
To monitor the problems of lighting points
To display function locally (same with the function of tower)
Local control function of lighting station (same with the function of tower)
The other temporary tower function of local lighting points (same with the function of tower)
Transferring function of control right:
The tower control center can transfer the control right to the maintenance center or the light station through the operation of flight controller.
The maintenance can accept the control right when the operation of flight controller and control center of tower is invalidated.
The lighting station can accept the control right when the operation of flight controller and control center of tower is invalidated.
The lighting station can return the control right back when the problems of maintenance center are fixed.
The lighting station can return the control right back when the problems of maintenance center are fixed.
In a special case, the right can be transferred between the control center and the lighting station.
Synchronous function
The maintenance center should submit all the updated data to the control center while it returns the authority back to the tower control center in order to make the synchronous data come true.
The lighting station should submit all the updated data to the maintenance center while it returns the authority back to the maintenance center. At the same time, the maintenance center should transmit the updated data to the tower control center to make the synchronous data come true.
The lighting station should submit all the updated data to the tower control center while it returns the authority back to the control center. At the same time, the tower control center should transmit the updated data to the maintenance center to make the synchronous data come true.
The optional solution for different level:
The first level: to monitor the loop and make the statistics of monitoring lighting point
System function of monitor the loop
More stable and easier to operate
To monitor the power of loop to warn in advance the problems of loop lighting point—more accurate than measure phase contrast method.
(Construction period is 2 months.)
The second level: to monitor the loop and each lighting point-- RS485 cables communication
All is the function of first level
To install the single light monitors/ communication cell on each lighting point.
To use the verified RS485 cables communication technique.
To use the special communication cables and photoelectric isolation technique.
(Construction period is 3 months.)
The third level: to monitor all loops and each lighting point-electronic line carrier technique.
All is the first-level function.
To install single monitor/communication cell on each lighting point.
Electronic line carrier technical communication
(Construction period is 6 months, to customize the new products, the uncertainty and the independence of the risk and the condition of the field. It is not suitable for the worse loop.)
Features of the system:
Powerful management function:
To provide the tools for installation and debugging
To create a database automatically when the installation and debugging is successful.
To test the plan design automatically or by hand
To create the testing report of whole/ part system automatically—system tests the database
To manage the testing results and reports automatically.
To provide the running report sheet, data and record (like the operation record, the alarm record, the maintenance record and so on)
The inquiring function should be provided in order to make the record of operation, alarm, maintenance and test.